FAQ's
Go to the File menu >
Properties. From here you can force Avance to load a
particular file at start-up, and also minimize at start-up.
If you have devices setup to run automatically in real time
then Avance will run statistical quality control quietly in
the background of your process.
Yes, this new feature allows Avance to write to
KepDirect OPC server
when statistical control changes states (in-control
or out-of-control). With OPC read and write capabilities you can talk to PLC's
and other automation devices, and directly integrate Avance
and SPC into your automated process.
Avance will only work for
kepdirect servers. In the near future we will extend the
compatibility to other servers.
Yes, you may import Excel
spread sheets using the Excel loader. Select File > Import >
Excel.
Avance is always working to
add specific serial devices to it's list of 'predefined'
serial devices. The advantage is that you don't have to
spend time configuring Avance to work with your device. You
simply select the device from a list and begin collecting
data. The generic device will work for most any serial
device, however you do have to setup the connection from the
setup dialog.
Yes, you may define your own
generic serial device or select a predefined tool such as Mitutoyo's
SPC input tool.
To setup the generic serial device go to Part Setup by clicking the Part Setup
icon located on the toolbar (hover over the icons with the mouse for
a brief description). From the Part Setup dialog click the New
Device icon, right click the newly created device, select edit. The
device setup dialog appears.
To use the preset serial
devices such as the Mitutoyo SPC input tool, select the settings menu -> data
input -> and then select the appropriate device.
Yes, you may do this from the
Part Setup dialog. Click the Part Setup icon located on the
toolbar (hover over the icons with the mouse for a brief
description). From the Part Setup dialog click on the part
or process you want work with. The variables for the
selected part or process will appear in the right hand
window. right click the variable you want to operate on,
select Edit. The Variable Setup dialog should appear. From
here you may set the specification limits, subgroup size,
and dispersion statistic.
Select the Data Management
icon from the toolbar (hover over the icons with the mouse
for a brief description). From within the Data Management
dialog you may merge parts and variables, sort data
chronologically, and filter data values using logical
operators.
Click the Part Setup icon
located on the toolbar (hover over the icons with the mouse
for a brief description). From the Part Setup dialog click
on the part or process you want work with. The variables for
the selected part or process will appear in the right hand
window. right click the variable you want to operate on,
select Edit. The Variable Setup dialog should appear. From
here you may set the specification limits, subgroup size,
and dispersion statistic.
The capability report exists
as 'CapabilityReport.html' in your working directory (if you
selected the default installation directory: c://program
files/Avance). You may view this file in any web browser to
print.
When you change the method
used for data input from manual input to a serial device or
to real time monitoring of the *.ez file the manual input
text box disappears. To make it visible again select the
settings menu > data input > manual input.
|